- Guard the AES output buffer against oversized advertisements
- Protect the cross-core MpptData hand-off with a critical section and
publish from a consistent snapshot
- Scan in 30s blocks and clear results between them: NimBLE 1.4.x only
frees its result list when a scan completes, and one entry is kept per
unique BLE address (including MAC-randomising phones)
- Do not let the forced-reconnect watchdog reset the reboot watchdog
- Publish discovery immediately after a reconnect instead of waiting for
the retry timer
- Pin espressif32 to 6.13.0 (Arduino core 2.0.17), the last platform
compatible with NimBLE-Arduino 1.4.x
- Document diagnostics, watchdogs and the data_age_s field